Skip to main content

Undefined (0x2000)

Undefined response

OK (0x2001)

Operation completed successfully

GeneralError (0x2002)

Operation did not complete, unknown error

SessionNotOpen (0x2003)

Session handle is not a currently open session

InvalidTransactionID (0x2004)

TransactionID is zero or does not refer to a valid transaction

OperationNotSupported (0x2005)

OperationCode appears valid but responder does not support it

ParameterNotSupported (0x2006)

Non-zero parameter specified but not used for this operation

IncompleteTransfer (0x2007)

Transfer did not complete, data should be discarded

InvalidStorageID (0x2008)

StorageID does not refer to a valid store on the device

InvalidObjectHandle (0x2009)

ObjectHandle does not refer to a valid object on the device

DevicePropNotSupported (0x200a)

DevicePropCode appears valid but not supported by device

InvalidObjectFormatCode (0x200b)

Device does not support the ObjectFormatCode in this context

StoreFull (0x200c)

Store referred to by operation is full

ObjectWriteProtected (0x200d)

Object referred to by operation is write-protected

StoreReadOnly (0x200e)

Store referred to by operation is read-only

AccessDenied (0x200f)

Access to data has been denied

NoThumbnailPresent (0x2010)

Object exists but contains no producible thumbnail

SelfTestFailed (0x2011)

Device failed internal self-test

PartialDeletion (0x2012)

Only a subset of objects were deleted

StoreNotAvailable (0x2013)

Store is not physically available

SpecificationByFormatUnsupported (0x2014)

Operation cannot specify action by format

NoValidObjectInfo (0x2015)

SendObject attempted without successful SendObjectInfo

InvalidCodeFormat (0x2016)

Data code does not have correct format

UnknownVendorCode (0x2017)

Vendor-extended code not supported by device

CaptureAlreadyTerminated (0x2018)

Capture session already terminated

DeviceBusy (0x2019)

Device or store is busy

InvalidParentObject (0x201a)

Object is not of type Association

InvalidDevicePropFormat (0x201b)

DevicePropDesc data set is incorrect size or format

InvalidDevicePropValue (0x201c)

DeviceProperty value not permitted by device

InvalidParameter (0x201d)

Parameter value is not legal

SessionAlreadyOpen (0x201e)

Session is already open

TransactionCancelled (0x201f)

Operation interrupted by manual cancellation

SpecificationOfDestinationUnsupported (0x2020)

Responder does not support initiator-specified destination

InvalidEnumHandle (0x2021)

EnumID parameter is invalid

NoStreamEnabled (0x2022)

Streaming operation started without enabled streams

InvalidDataset (0x2023)

Data set is malformed or has incorrect size